{"created":"2023-06-19T09:22:43.316952+00:00","id":1972,"links":{},"metadata":{"_buckets":{"deposit":"12b39ab7-9c79-409c-a6a9-72c9ae04fdfd"},"_deposit":{"created_by":4,"id":"1972","owners":[4],"pid":{"revision_id":0,"type":"depid","value":"1972"},"status":"published"},"_oai":{"id":"oai:auhw.repo.nii.ac.jp:00001972","sets":["52:260"]},"author_link":["11046","11045"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"Measurement of Distance between Spinous Processes of the Lumbar Spine : Assessment of Interrater Reliability , Concurrent Validity by Comparison between Palpation and Ultrasonograms"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-06","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"3","bibliographicPageStart":"1","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"青森県立保健大学雑誌"},{"bibliographic_title":"Journal of Aomori University of Health and Welfare","bibliographic_titleLang":"en"}]}]},"item_10002_description_19":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"本研究の目的は腰椎の棘突起間距離を触察法と超音波画像法の2つの方法を用いて計測し、その再現性と妥当性を検討することである。触察法は棘突起を皮膚上から触察し、計測点を決定して棘突起間距離をキャリパーを用いて計測する方法である。\n対象は健常男性36名、平均年齢20.1とした。\n触察法では2人の計測者間の計測値の級内相関係数は0.92〜0.98であり、良好な再現性が示された。さらに、超音波画像法による計測値を加えた3群間には統計学的な有意差が認められず、触察法と超音波画像法の再現性と妥当性が示され、臨床的に有用な計測法であることが示唆された。\nThis study was intended to measure the distance between spinous processes of the lumbar spine by two methods and examine the reliability of the data. One method was to palpate the spinous processes from over the skin, determine a land mark, and then use a caliper to measure the distance between two adjacent lumbar vertebrae (i.e., distance between the spinous processes). The other method was ultrasonographic measurement. The subjects were 36 healthy men with a mean age of 20.1 years. The reliability of the two measurements was subject to test-retest using intraclass correlation coefficient (ICC) , which represent interrater reliability between 2 raters, was 0.92 -0.98.There were no significant differences in the measurement values between the palpation by 2 raters\nand the ultrasonographic measurement. The palpitation method were considered acceptable and provided reliable results by comparison with the ultrasonographic method.","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.24552/00001963","subitem_identifier_reg_type":"JaLC"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1349-3272","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"佐藤, 秀一"},{"creatorName":"サトウ, シュウイチ","creatorNameLang":"ja-Kana"}],"nameIdentifiers":[{"nameIdentifier":"11045","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sato, Shuici","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"11046","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-02-11"}],"displaytype":"detail","filename":"AA11913394-00100001-0001.pdf","filesize":[{"value":"1.2 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"AA11913394-00100001-0001.pdf","url":"https://auhw.repo.nii.ac.jp/record/1972/files/AA11913394-00100001-0001.pdf"},"version_id":"40662f5c-cddb-42a2-bb68-93e5de467c66"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"棘突起間距離","subitem_subject_scheme":"Other"},{"subitem_subject":"触察","subitem_subject_scheme":"Other"},{"subitem_subject":"超音波画像","subitem_subject_scheme":"Other"},{"subitem_subject":"distance between spinous processes","subitem_subject_scheme":"Other"},{"subitem_subject":"palpation","subitem_subject_scheme":"Other"},{"subitem_subject":"ultrasonograms","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_thumbnail":{"attribute_name":"サムネイル","attribute_value_mlt":[{"subitem_thumbnail":[{"thumbnail_label":"AA11913394-00100001-0001-1.png","thumbnail_url":"/api/files/12b39ab7-9c79-409c-a6a9-72c9ae04fdfd/AA11913394-00100001-0001-1.png?versionId=7b33e02f-8932-42a8-ada6-1926f74d40c4"}]}]},"item_title":"腰椎の棘突起間距離の計測 : 触察法と超音波画像法の比較による再現性、妥当性の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"腰椎の棘突起間距離の計測 : 触察法と超音波画像法の比較による再現性、妥当性の検討"}]},"item_type_id":"10002","owner":"4","path":["260"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-05-26"},"publish_date":"2010-05-26","publish_status":"0","recid":"1972","relation_version_is_last":true,"title":["腰椎の棘突起間距離の計測 : 触察法と超音波画像法の比較による再現性、妥当性の検討"],"weko_creator_id":"4","weko_shared_id":-1},"updated":"2023-08-02T06:44:18.235013+00:00"}